MFG

Plastic Shrinkage Rates Table

Injection molding shrinkage rates for ABS, PP, PC, nylon, POM, PS, and PEEK, with flow and cross-flow values from producer datasheets.

Molded plastics shrink between about 0.4 percent for general-purpose polystyrene and 2.1 percent for acetal (POM) as they cool in the mold. This page lists the typical rate for each common injection molding resin, split into flow and cross-flow values where the producer publishes both, all taken from resin producer datasheets. The shrinkage mechanism itself, and how the molding cycle compensates for it, is covered on the injection molding hub; this table exists for dimensional planning.

How to read these shrinkage rates

Shrinkage is quoted as a percentage of the molded dimension. A 1.5 percent rate on a 100mm dimension means the part comes out about 1.5mm smaller than the cavity. Two numbers matter for every resin: the shrinkage along the melt flow direction and the shrinkage across it.

Flow and cross-flow are separate numbers

Semi-crystalline resins, and glass-filled grades especially, shrink differently along and across the flow. BASF’s 30 percent glass-filled PA66, A3EG6, lists 0.5 percent parallel to flow and 1.0 percent normal to it, so one direction of the same part shrinks twice as much as the other. That difference, not the average, is what warps parts. Unfilled acetal is the opposite case: BASF’s N2320 003 AT lists 2.10 percent parallel and 2.00 percent normal, close to isotropic, which is one reason POM still molds precise gears. Victrex PEEK 450G sits between, at 0.90 percent along flow and 1.3 percent across.

Amorphous and semi-crystalline resins behave differently

The three amorphous resins in the table, ABS, polystyrene, and polycarbonate, all land between roughly 0.4 and 0.8 percent, and their flow and cross-flow values stay close. The semi-crystalline group, PP, nylon, POM, and PEEK, starts near 0.9 percent and runs past 2 percent. Crystals pack tighter than random polymer chains, so semi-crystalline grades lose more volume as they freeze. That single fact explains most of the table.

Shrinkage rates by material

Each row states the producer’s published range or grade value. Producers cite ISO 294-4 as the mold-shrinkage test basis; the US styrenics sheets cite ASTM D955. Grade choice within a family moves the number, so treat family position as context and the grade datasheet as the value that counts.

POM and PP anchor the high end

Acetal copolymer is the high-shrinkage benchmark at 2.0 to 2.1 percent, nearly the same in every direction. Polypropylene spans 1.0 to 2.0 percent; Borealis prints that range for its RE420MO grade and states that wall thickness and molding parameters set where in the range a part lands.

Glass filler cuts shrinkage and adds direction

Glass fibers do not contract as the resin freezes, so swapping resin for fiber shrinks the whole part less. Moving from BASF’s unfilled A3K PA66, at 1.50 percent parallel and 1.80 percent normal, to the 30 percent glass A3EG6, at 0.5 percent parallel and 1.0 percent normal, cuts flow shrinkage to a third. The trade is anisotropy: the filled grade’s flow-to-cross-flow gap widens to 0.5 percentage points, and fibers aligned by flow pull dimensions toward the flow axis.

Using a rate to size a mold cavity

The first-pass rule is to divide the target dimension by 1 minus the shrinkage as a decimal, or just add the percentage to the steel, which is close enough at these rates. A 100mm PP dimension at the 1.5 percent midpoint needs a cavity near 101.5mm. Run the same sum at both ends of the range and the stakes appear: at 1.0 percent the cavity is 101.0mm, at 2.0 percent it is 102.0mm, and that 1.0mm spread is a process window a molder has to sit inside, not a rounding error.

Why the number is a range, not a constant

Borealis hangs its 1 to 2 percent PP range directly on wall thickness and molding parameters. Covestro’s Makrolon 2805 sheet separates a tested value, 0.65 percent parallel and 0.70 percent normal, from a 0.60 to 0.80 percent practical range drawn from field experience. Pack harder, run a hotter mold, or thicken a rib, and the same grade moves inside its band. Tooling decisions therefore lock the grade and the processing window together.

Moisture moves nylon after molding

Nylon is the one common resin whose dimensions keep changing in service. BASF’s A3K datasheet lists 2.5 to 3.1 percent moisture absorption at equilibrium, 23°C and 50 percent relative humidity, and 8 to 9 percent water uptake at saturation, and parts swell as they absorb. A nylon part measured dry out of the press is not the part you will measure in a humid plant a week later, so dimension nylon to its conditioned state.

Limitations

These are typical values for material families and named grades, gathered from producer datasheets (BASF editions 02/2026, Covestro, Borealis 2025, SABIC, Victrex), checked in August 2026. They support material comparison, tolerance budgeting, and first-pass cavity sizing. The number that governs a tool is the one on the datasheet of the exact grade being bought, confirmed with the molder against the part’s geometry, gating, and wall thickness. For the physics of shrink and warpage control in the molding cycle, see the injection molding hub, and for selection factors beyond shrinkage, see the materials overview.

About this data

Methodology
Typical molded shrinkage for common injection molding resins, with flow and cross-flow values where the source publishes both. Producer datasheets: SABIC CYCOLAC MG47F (ABS, SABIC method, 3.2mm plaque), Americas Styrenics (AmSty) STYRON 666D (GPPS, ASTM D955), Covestro Makrolon 2805 (PC, ISO 294-4), Borealis RE420MO (PP, product data sheet Ed. 3, April 2025), BASF Ultramid A3K and A3EG6 and Ultraform N2320 003 AT (editions 02/2026, ISO 294-4), Victrex PEEK 450G (ISO 294-4), accessed August 2026. Values support material comparison and first-pass cavity sizing; the governing number is the specific grade datasheet.
Sources
  • Every cell traces to a producer datasheet; ISO 294-4 is the mold-shrinkage basis producers cite, ASTM D955 for the US styrenics sheets. The ABS and GPPS ranges were independently verified 2026-08-16 against public lookpolymers.com mirrors of the SABIC and AmSty datasheets (MG47F 0.0050 to 0.0080 cm/cm flow, SABIC Method, 3.20mm plaque; 666D 0.0040 to 0.0070 cm/cm, ASTM D955); the MG47F mirror is a cited source and both URLs are recorded in the page source notes.
How to read this
Read flow (the direction melt travels from the gate) and cross-flow (at 90 degrees to it) as two separate numbers; the gap between them, not the average, is what warps parts. Use producer values for mold sizing and treat family position as context only.
Typical injection molding shrinkage rates by material
materialtypical shrinkage, flowtypical shrinkage, cross-flowpractical note
ABS, unfilled0.5 to 0.8%about 0.5%Amorphous; SABIC CYCOLAC MG47F flow range at 3.2mm plaque
PS, general purpose0.4 to 0.7%about 0.5%Amorphous; Americas Styrenics (AmSty) STYRON 666D flow range (ASTM D955)
PC, unfilled0.6 to 0.8%0.6 to 0.8%Amorphous; Covestro Makrolon 2805 lists 0.65% parallel, 0.70% normal (ISO 294-4)
PP, unfilled1.0 to 2.0%about 1.3%Semi-crystalline; Borealis RE420MO states 1 to 2% depending on wall thickness and molding
PA66 (nylon), unfilledabout 1.5%about 1.8%Semi-crystalline; BASF Ultramid A3K lists 1.50% parallel, 1.80% normal (ISO 294-4); parts swell with moisture after molding
PA66, 30% glass-filledabout 0.5%about 1.0%BASF A3EG6 (ISO 294-4); glass cuts flow shrinkage to a third of unfilled but widens the flow-to-cross gap to 0.5 points
POM (acetal copolymer)about 2.1%about 2.0%Highest common resin, nearly isotropic; BASF Ultraform N2320 003 AT lists 2.10% parallel, 2.00% normal
PEEK, unfilledabout 0.9%about 1.3%High-temperature semi-crystalline; Victrex 450G (ISO 294-4)

Frequently asked questions

What is a typical shrinkage rate for injection molding?
Amorphous resins such as ABS, polystyrene, and polycarbonate run about 0.4 to 0.8 percent. Semi-crystalline resins run higher: PP about 1.0 to 2.0 percent, unfilled nylon about 1.5 to 1.8 percent, and acetal about 2.0 to 2.1 percent. The table lists flow and cross-flow values for each material.
Which plastic shrinks the least?
General-purpose polystyrene and ABS sit at the low end, about 0.4 to 0.8 percent, and their flow and cross-flow shrinkage stay close to each other. Polycarbonate is similar at 0.6 to 0.8 percent. Low, uniform shrinkage is one reason these resins dominate housings and cosmetic parts.
Why does glass-filled nylon shrink less but warp more?
Glass fibers do not contract as the resin freezes, so 30 percent glass-filled PA66 (BASF A3EG6) shrinks 0.5 percent along the flow direction against 1.5 percent unfilled. The fibers align with flow, so cross-flow shrinkage stays near 1.0 percent, and that flow-to-cross gap is what distorts flat parts. Gate placement that balances flow direction matters more with filled grades.
How do I turn a shrinkage rate into a cavity dimension?
Divide the wanted part dimension by 1 minus the rate as a decimal. A 100mm PP dimension at 1.5 percent gives 100 divided by 0.985, about 101.5mm of steel. Run the same sum at both ends of the grade published range to see how much processing can move the dimension.
Does wall thickness change shrinkage?
Yes. Borealis ties its 1.0 to 2.0 percent PP range directly to wall thickness and molding parameters, and thicker sections cool more slowly, which grows crystals and shrink. A part with mixed wall thicknesses can shrink at different rates in different features, which is why uniform walls are a core design rule for molded parts.
Why do nylon parts keep changing size after molding?
PA66 absorbs moisture from the air. The BASF Ultramid A3K datasheet lists 2.5 to 3.1 percent moisture absorption at equilibrium (23°C, 50 percent relative humidity) and 8 to 9 percent water uptake at saturation, and the part swells as it takes that water in. Dimension nylon parts to the conditioned state, not the dry-as-molded state.
Are these table values exact for every grade?
No. They are producer datasheet values for named grades, so they support comparison and first-pass sizing. The governing number is on the datasheet of the exact grade you buy; Covestro, like other producers, notes that real parts vary with geometry, mold design, and processing.
Where do flow and cross-flow shrinkage numbers come from?
Producer datasheets measured to ISO 294-4, which molds a test plaque and reports shrinkage parallel and normal to flow. US styrenics sheets such as STYRON 666D cite the equivalent ASTM D955. Producer datasheets report the two directions separately, which is how the table shows both.

Sources